XTi2 Series Operation Manual
XTi 1002
XTi 2002
XTi 4002
XTi 6002
Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need
assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during
installation, operation or maintenance.
The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have occurred. To obtain the latest
Trademark Notice: Crown, Crown Audio, and Amcron are registered trademarks of Crown International. Other trademarks are the property of their respective owners.
Some models may be exported under the name Amcron®
©2011 by Harman International, 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000.
143060-2 - 4/11
XTi2 Series Power Amplifiers
DECLARATION OF CONFORMITY
Issued By: Harman International.
1718 W. Mishawaka Rd.
FOR FIELD SERVICE
QUESTIONS CALL:
1 800 342 6939
Elkhart, IN 46517 U.S.A.
European Representative’s Name and Address:
David J. Budge
10 Harvest Close
Yateley
GU46 6YS
United Kingdom
Equipment Type: Power amplifiers
Family Name: XTi2 Series
Model Names: XTi1002, XTi2002, XTi4002, XTi6002
EMC Standards:
EN 55103-1:1997 Electromagnetic Compatibility – Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for
Professional Use, Part 1: Emissions
EN 55103-1:1997 Magnetic Field Emissions-Annex A @ 10 cm and 1 M
EN 61000-3-2:2005 & Amd 1: 2008 Limits for Harmonic Current Emissions (equipment input current ≤16A per phase)
EN 61000-3-3:1998 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current ≤16A
EN 55022:2006 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class B
EN 55103-2:1997 Electromagnetic Compatibility – Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for
Professional Use, Part 2: Immunity
EN 61000-4-2:2001 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)
EN 61000-4-3:2006 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, Criteria A)
EN 61000-4-4:2007 Electrical Fast Transient/Burst Immunity (Criteria B)
EN 61000-4-5:2006 Surge Immunity (Criteria B)
EN 61000-4-6:2006 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)
EN 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variation
Safety Standard:
IEC 60065: 2001: 7Ed & Amd 1: 2005 Safety Requirements - Audio Video and Similar Electronic Apparatus
I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC,
and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC.
Signed
______________________
Scott Potosky
Title: Director of Engineering
Date of Issue: February 1, 2011
Operation Manual
page 3
XTi2 Series Power Amplifiers
Get Started
Stereo DSP Off
This is the default mode the amplifier is set to from the factory. The
amplifier is configured for stereo mode with all processing disabled.
1. Connect Left/Right signal source to Channel 1 and Channel 2 using
the XLR connectors.
2. Connect a speaker to each channel output using Speakon®, Banana
Plugs, or bare wire.
XTi 6002 back panel shown.
See page 9 for XTi 1002,
2002 and 4002 back panel.
WARNING: Before you start to set up your
amplifier, make sure you read and observe
the Important Safety Instructions found at
the beginning of this manual.
Factory Preset #2: BRIDGE
Putting the amplifier in BRIDGE (bridge-mono) mode delivers the power of
both amp channels into a single 8 or 4 ohm load. The XTi2 Series amplifiers
come pre-loaded with a preset that makes it easy to configure the amplifier for
this operation.
Before you get started ensure that you:
1. Connect signal source to Channel 1 and Channel 2 using XLR connectors
(the amplifier inputs will automatically be summed together when
selecting this preset).
2. Connector the speaker as shown.
a. If using the binding post outputs, connect the positive terminal of the speaker to the positive terminal of Channel 1 and
the negative terminal of the speaker to the positive terminal of Channel 2.
b. If using a Speakon® connector, connect the positive terminal of the speaker to 1+ and the negative terminal to 2+. Plug the
connector into the Channel 1 output only.
Follow these quick steps to configure the amplifier for BRIDGE operation:
1. Push the “Set/Enter” button and you will see the word “Preset” flashing.
2. Push the “Set/Enter” button again to enter the list of presets in the amplifier.
3. Push the “Next/Down” or “PREV/UP” button until the screen displays “Bridge”.
4. Push the “Set/Enter” button to confirm your selection.
NOTE: Custom wiring should
only be performed by qualified
personnel.
5. The display will now read “Bridge” with the Y icon and Bridge icon highlighted.
Operation Manual
page 4
XTi2 Series Power Amplifiers
Get Started
Factory Preset #3: XOVER
HIGH 2+/–
LOW 1+/–
Putting the amplifier in XOVER mode enables a 1.2kHz 4th order (24dB/octave)
filter that sends frequencies of 1.2kHz and below to Channel 1 output and
frequencies of 1.2kHz and above to Channel 2 output. The XTi2 Series amplifiers
come pre-loaded with a preset that makes it easy to configure the amplifier for
this operation.
Before you get started ensure that you:
1. Connect signal source to Channel 1 ONLY using an XLR connector (the
amplifier inputs will automatically be put into Y mode when selecting this
preset).
2. Connector the speaker as shown.
a. Connect the speaker you wish to receive the low and mid frequencies (1.2kHz and below) to Channel 1 output
using Speakon®, Banana Plugs, or bare wire.
b. Connect the speaker you wish to receive the high frequencies (1.2kHz and above) to Channel 2 output using Speakon®, Banana Plugs, or bare wire.
Follow these quick steps to configure the amplifier for XOVER operation:
1. Push the “Set/Enter” button and you will see the word “Preset” flashing.
2. Push the “Set/Enter” button again to enter the list of presets in the amplifier.
3. Push the “Next/Down” or “PREV/UP” button until the screen displays “BIAMP”.
4. Push the “Set/Enter” button to confirm your selection.
5. The display will now read “BIAMP” with the Y icon and XOV icon highlighted.
Factory Preset #4: BRG SUBS
Putting the amplifier in BRG SUBS (bridged subs) mode allows you to
bridge the amplifier for use with a single 8 or 4 ohm subwoofer. The inputs
are automatically summed, a 90Hz 4th order (24dB/octave) LowPass filter
is enabled, and the output mode is put into bridge-mono mode. The XTi2
Series amplifiers come pre-loaded with a preset that makes it easy to
configure the amplifier for this operation.
Before you get started ensure that you:
1. Connect signal source to Channel 1 and Channel 2 using XLR
connectors (the amplifier inputs will automatically be summed together
when selecting this preset).
2. Connector the speaker as shown.
a. If using the binding post outputs, connect the positive terminal of the
speaker to the positive terminal of Channel 1 and the negative terminal of the speaker to the positive terminal of Channel 2.
b. If using a Speakon® connector, connect the positive terminal of the speaker to 1+ and the negative terminal to 2+. Plug the connector into the Channel 1 output only.
Follow these quick steps to configure the amplifier for XOVER operation:
1. Push the “Set/Enter” button and you will see the word “Preset” flashing.
2. Push the “Set/Enter” button again to enter the list of presets in the amplifier.
3. Push the “Next/Down” or “PREV/UP” button until the screen displays “XOVER”.
4. Push the “Set/Enter” button to confirm your selection.
5. The display will now read “XOVER” with the Y icon and XOV icon highlighted.
Operation Manual
page 5
XTi2 Series Power Amplifiers
Get Started
Factory Preset #5: SUBSYNTH
Putting the amplifier in SUBSYNTH mode allows you to turn on the
SubHarmonic Synth feature for use with a subwoofer on both channels. The
inputs are automatically summed, a 90Hz 4th order (24dB/octave) filter is
enabled on both Channel 1 and Channel 2, and the SubHarmonic Synth feature
is turned on at +12dB level. The XTi2 Series amplifiers come pre-loaded with a
preset that makes it easy to configure the amplifier for this operation.
Before you get started ensure that you:
1. Connect signal source to Channel 1 and Channel 2 using XLR connectors
(the amplifier inputs will automatically be summed together when
selecting this preset).
2. Connector the speaker as shown.
a. Connect a speaker to each channel output using Speakon©, Banana
Plugs, or bare wire
Follow these quick steps to configure the amplifier for SUBSYNTH operation:
1. Push the “Set/Enter” button and you will see the word “Preset” flashing.
2. Push the “Set/Enter” button again to enter the list of presets in the amplifier.
3. Push the “Next/Down” or “PREV/UP” button until the screen displays “SUBSYNTH”.
4. Push the “Set/Enter” button to confirm your selection.
5. The display will now read “SUBSYNTH” with the Y icon and XOV icon highlighted.
Ensure Proper Cooling
When using an equipment rack, mount units directly on top of each other. Close any
open spaces in rack with blank panels. DO NOT block front or rear air vents. The side
walls of the rack should be a minimum of two inches (5.1 cm) away from the amplifier
sides, and the back of the rack should be open.
CAUTION: Before you begin installing your amplifier, make sure
it is disconnected from the power source, with the power switch
in the “off” position and all level controls turned completely
down (counterclockwise).
Operation Manual
page 6
XTi2 Series Power Amplifiers
Welcome
There’s no debate – when you choose Crown’s XTi2 Series, you’re choosing one of the most powerful and innovative amplifiers
on the market today. That’s because the all-new XTi2 Series amps continue to set the standard for unmatched performance and
value, delivering the goods night after night without breaking a sweat.
With such innovations as a universal tracking switch-mode power supply and a fully integrated suite of speaker processing
tools, these amps are at the top of their class when it comes to thermal efficiency and system flexibility.
You also have greatly improved control capabilities. The addition of Peak Plus™ Limiters gives you full command over
X
threshold, attack and release, and we enhanced the Subharmonic Synth so you can easily manage frequency, gain and filter
type, allowing for application specific tuning.
Plus, you’ll now be able to tailor fan speed for specific applications with the new Advanced Thermal controls and have software
visibility of the Power Supply Temperature and AC Line Voltage with the new Advanced Monitoring controls. Combine all of
that with integrated cast-aluminum rack handles for maximum durability and portability and you have the power to move you –
and the world.
Next Generation Features include:
tꢀ 1FBL9ꢀ1MVTꢀ-JNJUFSTꢀQSPWJEFꢀUIFꢀVMUJNBUFꢀJOꢀTZTUFNꢀQFSGPSNBODFꢀBOEꢀQSPUFDUJPOꢀCZꢀBMMPXJOH
full control over threshold, attack, and release
tꢀ &OIBODFEꢀ4VCIBSNPOJDꢀ4ZOUIꢀTFDUJPOꢀQSPWJEFTꢀVTFSꢀDPOUSPMꢀPWFSꢀDSPTTPWFSꢀGSFRVFODZꢃꢀNBYꢁꢀIBSNPOJDꢀGSFRVFODZꢃ
and 1 PEQ filter for system-specific tuning
tꢀ /FXꢀ"EWBODFEꢀ5IFSNBMꢀDPOUSPMTꢀBMMPXꢀGPSꢀꢄꢀVTFSꢅEFmOFEꢀGBOꢀNPEFꢀDPOUSPMTꢀoꢀOPSNBMꢃꢀFBSMZꢀ
and full speed – for matching fan performance to a specific application
tꢀ /FXꢀ"EWBODFEꢀ.POJUPSJOHꢀQSPWJEFTꢀTPGUXBSFꢀWJTJCJMJUZꢀPGꢀUIFꢀ1PXFSꢀ4VQQMZꢀ5FNQFSBUVSFꢀBOEꢀ"$ꢀ-JOFꢀ7PMUBHF
tꢀ *ODSFBTFEꢀOVNCFSꢀPGꢀQSFTFUTꢀUPꢀBꢀUPUBMꢀPGꢀꢆꢇꢈꢀꢉꢊꢀPGꢀXIJDIꢀBSFꢀVTFSꢀEFmOBCMF
tꢀ *OUFHSBUFEꢀoDBTUꢀBMVNJOVNꢀIBOEMFTꢀGPSꢀFBTZꢀIBOEMJOHꢀBOEꢀFOIBODFEꢀEVSBCJMJUZ
tꢀ -PDLJOHꢀQPXFSꢀDPSEꢀDMJQꢀQSPWJEFTꢀBꢀTFDVSFꢀDPOOFDUJPOꢀCFUXFFOꢀUIFꢀBNQMJmFSꢀBOEꢀQPXFSꢀDPSE
tꢀ 6QEBUFEꢀ)J2OFUꢀ#BOEꢀ.BOBHFSꢀBOEꢀ4ZTUFNꢀ"SDIJUFDUꢀDPOUSPMꢀTPGUXBSF
How to Use This Manual
This manual provides you with the necessary information to safely and correctly setup and operate your amplifier. It does
not cover every aspect of installation, setup, or operation that might occur under every condition. For additional information,
system installer or retailer.
We strongly suggest you read all instructions, warnings and cautions contained in this manual. Also, for your protection,
please send in your warranty registration card today. And save your bill of sale – it’s your official proof of purchase.
Operation Manual
page 7
XTi2 Series Power Amplifiers
Front Panel Features
Indicators:
Ready Indicator: Two green LEDs, one for each channel, illuminate when the amplifier is ready to produce audio.
Signal Presence Indicator: Two green LEDs, one for each channel, illuminate when the channel input exceeds -40dBu. Useful for troubleshooting cable runs.
-20 Indicator: Two green LEDs, one for each channel, illuminate when the output signal exceeds -20dB below clip.
-10 Indicator: Two green LEDs, one for each channel, illuminate when the output signal exceeds -10dB below clip.
Clip Indicator: Two red LEDs, one for each channel, illuminate at the threshold of audible distortion.
Thermal Indicator: Two red LEDs, one for each channel, illuminate when thermal compression begins due to excessive temperature conditions.
Cooling Vents:
Front to rear forced air flow.
Gain (Level) Controls:
Two black rotary level controls,
one for each channel.
LCD Screen:
Backlit liquid crystal display
shows enabled presets and
speaker processing.
Power Button & Indicator:
Turns amplifier power on and off.
Blue LED will illuminate when
power is turned on.
Sel/Prev/Next Buttons:
Three buttons located
underneath the LCD screen
used to access menu items
and front panel lockout.
WARNING: Never connect the output to a power supply,
battery or power main. Electrical shock may result.
Operation Manual
page 8
XTi2 Series Power Amplifiers
Back Panel Features
XTi 1002, 2002, 4002
Binding Post Output Jacks:
One pair per channel, accepts banana plugs or
bare wire. Note: Binding Post outputs on European
Power Cord Clip:
Mounting points for
securing, included
power cord clip.
Input Connector:
Two 3-pin XLR input
connectors are provided
(one per channel).
models come with safety plugs installed to prevent
European power plugs from being inserted. The
side entry positions for these connectors should
be used with European models.
Fans:
Provide front to back
forced airflow for cooling.
4-Pole Speakon® Output Connectors:
These two connectors accept 2-pole and 4-pole
Speakon© connectors. The channel 1 connector is
wired for both channels so it can be used for
bridge-mono wiring or stereo wiring of two
speakers to a single Speakon.
Link/Out Connector:
HiQnet USB Connector:
Type B USB connector allows
you to connect the amplifier to
a computer for use with
System Architect™ and Band
Manager™ software.
AC Power
Connector
Two 3-pin XLR output
connectors are provided
(one per channel) to
loop-thru signal from one
amplifier to another.
XTi 6002
Power Cord Clip:
Binding Post Output Jacks:
Mounting points for securing,
included power cord clip.
One pair per channel, accepts banana plugs or
bare wire. Note: Binding Post outputs on European
models come with safety plugs installed to prevent
European power plugs from being inserted. The
side entry positions for these connectors should
be used with European models.
Input Connector:
Two 3-pin XLR input
connectors are provided
(one per channel).
Fans:
Provide front to back
forced airflow for cooling.
AC Power
Connector
Circuit Breaker:
Provides overload protection
4-Pole Speakon® Output Connectors:
These two connectors accept 2-pole and 4-pole
Speakon© connectors. The channel 1 connector is
wired for both channels so it can be used for
bridge-mono wiring or stereo wiring of two
speakers to a single Speakon.
Link/Out Connector:
HiQnet USB Connector:
Type B USB connector allows
you to connect the amplifier to
a computer for use with
System Architect™ and Band
Manager™ software.
Two 3-pin XLR output
connectors are provided
(one per channel) to
loop-thru signal from one
amplifier to another.
Operation Manual
page 9
XTi2 Series Power Amplifiers
Front Panel Navigation
From the front panel, you can change settings for several of the amplifier’s integrated signal processing features: Input Y,
Crossover Frequency, EQ, Delay, Limiting, and Stereo/Bridge-Mono. The Icons in the display illuminate to show which
features are currently applied and turned on.
When you power-on the amplifier for the first time, the LCD screen displays “DSP OFF” (no DSP is applied). Subsequent
power-ons display the preset that was active when you last shut off the amplifier.
The figure below shows the Menu Tree, which is the navigation path of options in the Menu. It shows how you navigate
through the front panel and which settings are available from the front panel. For full access to all features, it is required that
you hook up the amplifier via USB to a computer and run either HiQnet System Architect™ or Band Manager™ software.
Menu Tree
MENU TREE
Power-up
CURRENT PRESET
Sel
Next or Prev
FLASHING “PRESET” TEXT
FLASHING “CONFIG” TEXT
Sel
Sel
Next
FLASHING “PRESET” ICON
Sel
Press Next to see
each processor’s
options, then press
Sel to select an option.
DSP PROCESSES
(ICONS on screen)
CH1+CH2
INPUT Y
STEREO
Next
Y
Sel
PRESETS
(TEXT on screen)
Next
OFF, 90 Hz, 100 Hz, 1200 Hz,
1500 Hz, 2000 Hz, 2-CH SUB,
CUSTOM
XOV
Sel
Next
DSP OFF
Next
BRIDGE
Next
XOVER
Next
EQ OUT
EQ Ch. 1
Sel
EQ IN
Prev
Next
EQ OUT
EQ Ch. 2
Sel
EQ IN
Prev
BRG SUBS
Next
SUB SYNTH
Next
USER PRESETS
6-50
Next
CURRENT, OFF, 50, 40, 30,
20,10, 9, 8, 7, 6, 5, 4, 3, 2, 1
DELAY Ch. 1
Sel
Next
CURRENT, OFF, 50, 40, 30,
20,10, 9, 8, 7, 6, 5, 4, 3, 2, 1
DELAY Ch. 2
Sel
Next
Next
CURRENT, OFF, –0.5 dB,
–1.0 dB, –1.5 dB... –40 dB
LIM Ch. 1
Sel
Sel
Doing nothing returns you to the
CURRENT PRESET after a timeout delay.
Next
CURRENT, OFF, –0.5 dB,
–1.0 dB, –1.5 dB... –40 dB
LIM Ch. 2
Sel
Starting from the CURRENT PRESET,
Next
BRIDGE
STEREO
Sel > Sel > Next goes to presets.
STEREO/BRIDGE MONO
Sel
Sel > Next > Sel lets you
configure the DSP processes.
Prev
Navigating the LCD Screen Menu: Basics
To step through the Menu options, press the Sel, Next or Prev buttons as described in the menu tree above. Icons
illuminated at the top of the screen show which DSP functions are active with the current preset.
When you are modifying a preset, its icon flashes. You can scroll through its settings with the Prev and Next buttons.
When you see the desired setting, select it by pressing Sel. Doing nothing returns you to the current preset after ten seconds.
In the LCD screen, if the Preset Icon is lit, the current preset is unchanged from its stored settings. If the Custom Icon is lit,
the current preset has been changed from its stored settings.
Operation Manual
page 10
XTi2 Series Power Amplifiers
Integrated Processing Features
The XTi2 Series amplifiers include a number of integrated processing features which appear as icons on the front panel LCD
screen. They are described below:
NOTE: System Architect Software is required to have full control over all Integrated Processing Features which can be
you will need USB Hub. We recommend using a Powered USB Hub.
Input Mode
tꢀ 4UFSFPꢀꢀꢅꢀ*OꢀUIJTꢀNPEFꢃꢀ$IBOOFMꢀꢋꢀJOQVUꢀHPFTꢀUPꢀ$IBOOFMꢀꢋꢀPVUQVUꢀBOEꢀ$IBOOFMꢀꢌꢀJOQVUꢀHPFTꢀUPꢀ$IBOOFMꢀꢌꢀPVUQVUꢁꢀ5IJTꢀJTꢀ
the mode the amplifier is configured for from the factory.
tꢀ 46.ꢀ $)ꢋꢀꢍꢀ$)ꢌꢎꢀoꢀ*OꢀUIJTꢀNPEFꢃꢀUIFꢀ$IBOOFMꢀꢋꢀJOQVUꢀTJHOBMꢀBOEꢀ$IBOOFMꢀꢌꢀJOQVUꢀTJHOBMꢀBSFꢀTVNNFEꢀBOEꢀGFEꢀUPꢀCPUIꢀ
output channels. This provides a 6 dB level boost.
tꢀ *OQVUꢀ:ꢀoꢀ*OꢀUIJTꢀNPEFꢃꢀUIFꢀ$IBOOFMꢀꢋꢀJOQVUꢀTJHOBMꢀJTꢀTFOUꢀUPꢀUIFꢀ$IBOOFMꢀꢋꢀBOEꢀ$IBOOFMꢀꢌꢀPVUQVUꢁꢀ5IFꢀDIBOOFMꢀꢌꢀJOQVUꢀ
signal is ignored.
Output Mode
tꢀ 4UFSFPꢀoꢀ*OꢀUIJTꢀNPEFꢃꢀUIFꢀBNQMJmFSꢀTFOETꢀ$IBOOFMꢀꢋꢀJOQVUꢀTJHOBMꢀUPꢀUIFꢀ$IBOOFMꢀꢋꢀPVUQVUꢀBOEꢀUIFꢀ$IBOOFMꢀꢌꢀJOQVUꢀTJHOBMꢀ
to the Channel 2 output.
tꢀ #SJEHFꢅ.POPꢀoꢀ*OꢀUIJTꢀNPEFꢃꢀUIFꢀQPXFSꢀPGꢀCPUIꢀBNQMJmFSꢀDIBOOFMTꢀBSFꢀEFMJWFSFEꢀJOUPꢀBꢀTJOHMFꢀꢏꢀPSꢀꢉꢀPINꢀMPBEꢁꢀ
Subharmonic Synth
The Subharmonic Synth feature takes the low frequencies and “synthesizes” or creates new frequencies that are one octave
lower. The two signals are then summed together. Also new, are two user adjustable parametric EQ filters and crossover
frequency filter. These can be used to “shape” the sound and enhance the desired effect.
Equalization
The XTi2 Series provides two blocks of equalization in the signal processing. The input EQ block is before the crossover and
is usually used for the room EQ. The output EQ block is after the crossover and is usually used for speaking tuning.
Input EQ: This input EQ block provides 6 filters per channel each with frequency, gain, and Q that is user controllable.
This block also has a High and Low Shelf Filter per channel which has gain and frequency control.
Output EQ: This output EQ block provides 8 filters per channel each with frequency, gain, and Q control that is user
controllable.
Crossover:
The crossover section provides users with the ability to enable a HighPass and LowPass filter per channel along with
BandPass gain and the ability to change the polarity. This allows the Crossover section to be customized to most system
configurations.
For the HighPass and LowPass Filters, you have the choice of the following filters: Butterworth 6dB/oct, Butterworth 12dB/oct,
Butterworth 18dB/oct, Butterworth 24dB/oct, Butterworth 48dB/oct, Linkwitz-Riley 24dB/oct, and Linkwitz-Riley 48dB/oct.
The BandPass gain provides you with -15dB to +15dB of gain.
Delay
There is up to 50msec of delay available in the signal processing for time aligning your speakers. The software allows you to
enter the amount of delay needed in the form of seconds, feet, or meters and does the calculation for you.
Peak Plus Limiter:
X
Feed-forward output limiter with user-adjustable attack, release and threshold (0.1 dB resolution), plus integrated feedback
limiter to minimize amplifier clipping.
Operation Manual
page 11
XTi2 Series Power Amplifiers
Integrated Processing Features
Advanced Thermal Control
In this section, you can tailor the fan speed to specific applications. You have the choice of the following modes:
tꢀ /PSNBM
tꢀ &BSMZ
tꢀ 'VMMꢅ4QFFE
The fan mode can be changed using the front panel buttons at start-up or in the software. The default mode is normal and
should work fine for most applications. Early mode turns the fan on sooner at a “lower” temperature, and Full-speed mode
turns the fan on full-speed full-time. Full-speed mode is not recommended for “dirty” environments.
Advanced Monitoring
This feature allows you to have software visibility of both the Power Supply Temperature and AC Line voltage. AC Line
voltage is “derived” from the amplifier rail voltage and is an approximation of the AC line voltage. This allows you to monitor
the health of your amplifiers and provides for troubleshooting.
Front Panel Lock-Out
To disable or lock the buttons from the front panel, hold the Prev and Next at the same time until the screen says “locked”.
The rotary knobs (attenuators) will still operate. To unlock, hold Prev and Next until the screen says “unlocked”.
The front panel can also be locked out from the software as well from the main panel. However once it is locked in
the software, it can only be unlocked from the software. You cannot unlock from the front panel. The rotary knobs
(attenuators) will still operate.
Operation Manual
page 12
XTi2 Serie Bedienungsanleitung
XTi 1002
XTi 2002
XTi 4002
XTi 6002
Weitere Sprachversionen: Um Informationen über die Nutzung dieses Produktes in anderen Sprachen zu erhalten, wenden Sie sich bitte an Ihren örtlichen Crown-
Händler. Wenn Sie Hilfe dabei benötigen, Ihren örtlichen Händler ausfindig zu machen, kontaktieren Sie Crown bitte unter 574-294-8000.
Dieses Handbuch enthält nicht alle Einzelheiten zu Design, Herstellung oder Varianten des Gerätes. Es deckt auch nicht jeden möglichen Fall ab, der während Installation,
Betrieb oder Wartung auftreten könnte.
Die in diesem Handbuch enthaltenen Informationen waren bei Erscheinungsdatum zutreffend. Es können jedoch Aktualisierungen zu diesen Informationen vorliegen. Um die
Rechtlicher Hinweis: Crown, Crown Audio und Amcron sind eingetragene Handelsmarken von Crown International. Sonstige Handelsmarken sind das Eigentum ihrer
jeweiligen Eigentümer. Spätere Versionen dieses Handbuchs und zusätzliche Informationen zu diesem Produkt stehen gegebenenfalls auf der Crown-Webseite auf
Einige Modelle können unter dem Namen Amcron® exportiert werden.
©2011 by Harman International, 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 USA, Telefon: 574-294-8000.
143060-2 - 4/11
XTi2 Series Power Amplifiers
Inbetriebnahme
Stereo DSP AUS
Dies ist die Standardwerkseinstellung des Verstärkers.
Der Verstärker ist für den Stereomodus konfiguriert,
wobei sämtliche Verarbeitungsfunktionen deaktiviert sind.
1. Schließen Sie die rechte/linke Signalquelle mit Hilfe
der XLR-Stecker an Kanal 1 und Kanal 2 an
2. Schließen Sie mit Hilfe von Speakon®, Bananensteckern oder
blankem Draht einen Lautsprecher an jeden Kanalausgang an
Rückwand des XTi 6002.
ACHTUNG: Vor Inbetriebnahme Ihres
Die Rückwände des XTi
1002, 2002 und 4002
finden Sie auf Seite 9.
Verstärkers lesen und befolgen Sie bitte die
wichtigen Sicherheitsanweisungen, die Sie
zu Beginn dieser Bedienungsanleitung finden.
Werksvoreinstellung Nr. 2: BRÜCKE
Wenn der Verstärker in den BRÜCKEN-Modus (Brücke-Mono) versetzt wird,
wird die Leistung beider Verstärkerkanäle als einzelne 8 oder 4 Ohm-
Last bereitgestellt. Die Verstärker der Serie XTi2 sind werkseitig mit einer
Voreinstellung versehen, die die Konfiguration des Verstärkers für diesen
Betrieb erleichtert.
Bevor Sie beginnen, stellen Sie sicher, dass Sie:
1. die Signalquelle mit Hilfe von XLR-Steckern an Kanal 1 und Kanal 2
angeschlossen haben (die Verstärkereingänge werden automatisch
summiert, wenn diese Voreinstellung gewählt wird),
2. den Lautsprecher wie gezeigt angeschlossen haben.
a. Wenn Sie die Verbindungsklemmenausgänge verwenden, schließen Sie die positive Klemme des Lautsprechers an die
positive Klemme von Kanal 1 und die negative Klemme des Lautsprechers an die positive Klemme von Kanal 2 an
b. Wenn Sie einen Speakon® Stecker verwenden, schließen Sie die positive Klemme des Lautsprechers an 1+ und
die negative Klemme an 2+ an. Stecken Sie den Stecker nur in den Ausgang von Kanal 1 ein
Folgen Sie diesen einfachen Schritten zur Konfiguration des Verstärkers für den BRÜCKEN-Betrieb:
1. Drücken Sie die Taste "Set/Enter", so dass "Preset" blinkt
ANMERKUNG: Individuelle
Verdrahtungen sind nur von
qualifizierten Fachkräften
durchzuführen.
2. Drücken Sie die Taste "Set/Enter" noch einmal, um die Liste der Voreinstellungen in den Verstärker einzugeben
3. Drücken Sie "Next/Down" oder “PREV/UP”, bis das Display "Bridge" anzeigt
4. Drücken Sie "Set/Enter" zur Bestätigung Ihrer Auswahl
5. Das Display zeigt jetzt "Bridge" an und das Y-Symbol und Brückensymbol sind hervorgehoben
Operation Manual
page 14
XTi2 Series Power Amplifiers
Inbetriebnahme
Werksvoreinstellung Nr. 3: XOVER
HIGH 2+/–
LOW 1+/–
Im XOVER-Modus wird ein 1,2 kHz Filter der 4. Ordnung (24dB/Oktave)
aktiviert, der Frequenzen von 1,2 kHz und weniger an Kanalausgang 1 und
Frequenzen von 1,2 kHz und mehr an Kanalausgang 2 sendet. Die Verstärker
der Serie XTi2 sind werkseitig mit einer Voreinstellung versehen, die die
Konfiguration des Verstärkers für diesen Betrieb erleichtert.
Bevor Sie beginnen, stellen Sie sicher, dass Sie:
1. die Signalquelle mit Hilfe eines XLR-Steckers NUR an Kanal 1
angeschlossen haben (die Verstärkereingänge werden automatisch in den
Y-Modus versetzt, wenn diese Voreinstellung gewählt wird),
2. den Lautsprecher wie gezeigt angeschlossen haben.
a. Schließen Sie mit Hilfe von Speakon®, Bananensteckern oder blankem Draht den Lautsprecher, der die
niedrigen und mittleren Frequenzen (1,2 kHz und weniger) empfangen soll, an Kanalausgang 1 an
b. Schließen Sie mit Hilfe von Speakon®, Bananensteckern oder blankem Draht den Lautsprecher,
der die hohen Frequenzen (1,2 kHz und mehr) empfangen soll, an Kanalausgang 2 an
Folgen Sie diesen einfachen Schritten zur Konfiguration des Verstärkers für den XOVER-Betrieb:
1. Drücken Sie die Taste "Set/Enter", so dass "Preset" blinkt
2. Drücken Sie die Taste "Set/Enter" noch einmal, um die Liste der Voreinstellungen in den Verstärker einzugeben
3. Drücken Sie "Next/Down" oder “PREV/UP”, bis das Display "BIAMP" anzeigt
4. Drücken Sie "Set/Enter" zur Bestätigung Ihrer Auswahl
5. Das Display zeigt jetzt "BIAMP" an und das Y-Symbol und XOV-Symbol sind hervorgehoben
Werksvoreinstellung Nr. 4: BRG SUBS
Im Modus BRG SUBS (Bridged Subs - überbrückte Subwoofer) können
Sie den Verstärker für die Verwendung eines einzelnen 8 oder 4 Ohm-
Subwoofer überbrücken. Die Eingänge werden automatisch summiert,
ein 90Hz Tiefpassfilter 4er Ordnung (24 dB/Oktave) wird aktiviert und der
Ausgangsmodus wird in den Bridge-Mono-Modus versetzt. Die Verstärker
der Serie XTi2 sind werkseitig mit einer Voreinstellung versehen, die die
Konfiguration des Verstärkers für diesen Betrieb erleichtert.
Bevor Sie beginnen, stellen Sie sicher, dass Sie:
1. die Signalquelle mit Hilfe von XLR-Steckern an Kanal 1 und Kanal 2
angeschlossen haben (die Verstärkereingänge werden automatisch
summiert, wenn diese Voreinstellung gewählt wird),
2. den Lautsprecher wie gezeigt angeschlossen haben.
a. Wenn Sie die Verbindungsklemmenausgänge verwenden, schließen Sie die positive Klemme des Lautsprechers an
die positive Klemme von Kanal 1 und die negative Klemme des Lautsprechers an die positive Klemme von Kanal 2 an
b. Wenn Sie einen Speakon® Stecker verwenden, schließen Sie die positive Klemme des Lautsprechers an 1+ und die negative Klemme an 2+ an. Stecken Sie den
Stecker nur in den Ausgang von Kanal 1 ein
Folgen Sie diesen einfachen Schritten zur Konfiguration des Verstärkers für den XOVER-Betrieb:
1. Drücken Sie die Taste "Set/Enter", so dass "Preset" blinkt
2. Drücken Sie die Taste "Set/Enter" noch einmal, um die Liste der Voreinstellungen in den Verstärker einzugeben
3. Drücken Sie "Next/Down" oder “PREV/UP”, bis das Display "XOVER" anzeigt
4. Drücken Sie "Set/Enter" zur Bestätigung Ihrer Auswahl
5. Das Display zeigt jetzt "XOVER" an und das Y-Symbol und XOV-Symbol sind hervorgehoben.
Operation Manual
page 15
XTi2 Series Power Amplifiers
Inbetriebnahme
Werksvoreinstellung Nr. 5: SUBSYNTH
Im SUBSYNTH Modus können Sie die SubHarmonic Synth-Funktion
zur Verwendung mit einem Subwoofer auf beiden Kanälen aktivieren.
Die Eingänge werden automatisch summiert, ein 90Hz Tiefpassfilter 4er
Ordnung (24 dB/Oktave) wird sowohl auf Kanal 1 als auch auf Kanal 2
aktiviert und die SubHarmonic Synth-Funktion wird bei einem Pegel
von +12dB aktiviert. Die Verstärker der Serie XTi2 sind werkseitig mit einer
Voreinstellung versehen, die die Konfiguration des Verstärkers für diesen
Betrieb erleichtert.
Bevor Sie beginnen, stellen Sie sicher, dass Sie:
1. die Signalquelle mit Hilfe von XLR-Steckern an Kanal 1 und Kanal 2
angeschlossen haben (die Verstärkereingänge werden automatisch
summiert, wenn diese Voreinstellung gewählt wird),
2. den Lautsprecher wie gezeigt angeschlossen haben
a. Schließen Sie mit Hilfe von Speakon®, Bananensteckern oder blankem Draht einen Lautsprecher an jeden Kanalausgang an
Folgen Sie diesen einfachen Schritten zur Konfiguration des Verstärkers für den SUBSYNTH-Betrieb:
1. Drücken Sie die Taste "Set/Enter", so dass "Preset" blinkt
2. Drücken Sie die Taste "Set/Enter" noch einmal, um die Liste der Voreinstellungen in den Verstärker einzugeben
3. Drücken Sie "Next/Down" oder “PREV/UP”, bis das Display "SUBSYNTH" anzeigt
4. Drücken Sie "Set/Enter" zur Bestätigung Ihrer Auswahl
5. Das Display zeigt jetzt "SUBSYNTH" an und das Y-Symbol und XOV-Symbol sind hervorgehoben
Stellen Sie eine korrekte Kühlung sicher
Bei Verwendung eines Rack montieren Sie die Einheiten direkt übereinander.
Verschließen Sie Freiräume im Rack mit Blindplatten. Blockieren Sie die Belüftungen
an der Vorder- und Rückseite NICHT. Die Seitenwände des Rack müssen einen
Mindestabstand von 5,1 cm (2 Zoll) zu den Seitenwänden des Verstärkers aufweisen
und die Rückseite des Rack muss offen sein.
VORSICHT: Vor der Installation Ihres Verstärkers stellen
Sie sicher, dass er von der Stromquelle getrennt ist, der
Hauptschalter auf "AUS" steht und alle Pegelregler
vollständig zurückgedreht sind (gegen den Uhrzeigersinn).
Operation Manual
page 16
|